All Relations between ct and retina cone cell

Publication Sentence Publish Date Extraction Date Species
Ioannis Kakkos, Theodoros P Vagenas, Anna Zygogianni, George K Matsopoulo. Towards Automation in Radiotherapy Planning: A Deep Learning Approach for the Delineation of Parotid Glands in Head and Neck Cancer. Bioengineering (Basel, Switzerland). vol 11. issue 3. 2024-03-27. PMID:38534488. to assess replanning necessity during treatment, an additional registration method is implemented on the segmentation output, aligning images of different modalities (computed tomography (ct) and cone beam ct (cbct)). 2024-03-27 2024-03-29 Not clear
Matheus L Oliveira, Michael M Bornstein, Dorothea Dagassan-Bernd. Feasibility of frozen soft tissues to simulate fresh soft tissue conditions in cone beam CT scans. Dento maxillo facial radiology. vol 53. issue 3. 2024-03-25. PMID:38290763. feasibility of frozen soft tissues to simulate fresh soft tissue conditions in cone beam ct scans. 2024-03-25 2024-03-27 Not clear
Matheus L Oliveira, Michael M Bornstein, Dorothea Dagassan-Bernd. Feasibility of frozen soft tissues to simulate fresh soft tissue conditions in cone beam CT scans. Dento maxillo facial radiology. vol 53. issue 3. 2024-03-25. PMID:38290763. to evaluate the feasibility of frozen soft tissues in simulating fresh soft tissues of pig mandibles using cone beam ct (cbct). 2024-03-25 2024-03-27 Not clear
Yaren Dogan, Yigit Siri. Do Cone Beam CT Picture Archiving and Communication Systems Viewer Interfaces Meet the Expectations of Dental Professionals From a Usability Perspective? Cureus. vol 16. issue 2. 2024-03-19. PMID:38500918. do cone beam ct picture archiving and communication systems viewer interfaces meet the expectations of dental professionals from a usability perspective? 2024-03-19 2024-03-21 mouse
Florent Carsuzaa, Mélanie Dore, Sabah Falek, Grégory Delpon, Julien Drouet, Juliette Tharia. [Prevention, diagnosis and management of osteoradionecrosis: Where do we stand?] Bulletin du cancer. 2024-03-13. PMID:38480057. the diagnosis of orn requires to eliminate tumor recurrence then is based on clinical arguments and imaging by ct or cone beam evolving in a chronic mode (more than 3-6 months). 2024-03-13 2024-03-16 Not clear
Ruben Geevarghese, Sylvain Bodard, Leo Razakamanantsoa, Clement Marcelin, Elena N Petre, Anthony Dohan, Adrian Kastler, Julien Frandon, Matthias Barral, Philippe Soyer, Francois H Corneli. Interventional Oncology: 2024 Update. Canadian Association of Radiologists journal = Journal l'Association canadienne des radiologistes. 2024-03-06. PMID:38444144. imaging modalities, including functional mri, pet and cone beam ct are reshaping imaging and precision. 2024-03-06 2024-03-08 Not clear
Samuel N Andersen, Mark D Bonnen, Michelle S Ludwig, Shraddha M Dalwad. Quality Assurance for Stereotactic Body Radiation Therapy for Gynecologic Malignancies. Cureus. vol 16. issue 2. 2024-03-04. PMID:38435154. prior to each fraction, the simulation position is reproduced and verified with on-table cone beam ct, and the position is maintained with whole-body immobilization. 2024-03-04 2024-03-06 Not clear
Ana Luiza E Carneiro, Isabella N R Reis, Fernando Valentim Bitencourt, Daniela M R A Salgado, Claudio Costa, Rubens Spin-Net. Accuracy of linear measurements for implant planning based on low-dose Cone Beam CT protocols: a systematic review and meta-analysisAccuracy of low-dose CBCT: a systematic review and meta-analysis. Dento maxillo facial radiology. 2024-03-02. PMID:38429951. accuracy of linear measurements for implant planning based on low-dose cone beam ct protocols: a systematic review and meta-analysisaccuracy of low-dose cbct: a systematic review and meta-analysis. 2024-03-02 2024-03-04 Not clear
Zafeiroula Yfanti, Sotirios Tetradis, Nikolaos G Nikitakis, Konstantina Eleni Alexiou, Nikolaos Makris, Christos Angelopoulos, Kostas Tsiklaki. Radiologic findings of osteonecrosis, osteoradionecrosis, osteomyelitis and jaw metastatic disease with cone beam CT. European journal of radiology. vol 173. 2024-03-01. PMID:38428257. radiologic findings of osteonecrosis, osteoradionecrosis, osteomyelitis and jaw metastatic disease with cone beam ct. 2024-03-01 2024-03-04 Not clear
Ryo Nakayama, Kosuke Matsubar. [The Study for Standardization of Dose Evaluation Method in Cone-beam CT]. Nihon Hoshasen Gijutsu Gakkai zasshi. 2024-02-28. PMID:38417899. this study aimed to compare the dose evaluation methods by constructing simulation models using the monte carlo calculation code and propose an evaluation method for cone beam ct (cbct) that ensures accuracy and practicality. 2024-02-28 2024-03-02 Not clear
Arif Rashid, Lee Feinberg, Kathleen Fa. The Application of Cone Beam Computed Tomography (CBCT) on the Diagnosis and Management of Maxillofacial Trauma. Diagnostics (Basel, Switzerland). vol 14. issue 4. 2024-02-24. PMID:38396412. however, the emergence of cone beam ct in recent years has led to its wider applications, including facial trauma assessment. 2024-02-24 2024-02-26 Not clear
Rocío Vidales-Miranda, Gustavo Adolfo Fiori-Chíncaro, Ana María Agudelo-Botero, Jhoana Mercedes Llaguno-Rubi. [Use of current imaging tools for the study of odontogenic myxoma. A review of the literature]. Revista Cientifica Odontologica (Universidad Cientifica del Sur). vol 10. issue 2. 2024-02-23. PMID:38389660. tumor cells spread in the intratrabecular space beyond the bone limit, making it difficult to determine the edge of the tumor, even without cortical continuity, presenting intermittent direct contact with soft tissue; the appearance can be unilocular (small lesions), or commonly the typical image is that of a destructive lesion with poorly defined borders with a multilocular growth pattern, for which the use of advanced medical images such as cone beam computed tomography (cthc), computed tomography (ct), magnetic resonance imaging (mri), are useful to establish an adequate diagnosis with the ability to point out the characteristics of om with precision and three-dimensional perspective. 2024-02-23 2024-02-25 Not clear
Jieming Zhang, Chang Qing, Yu Li, Yaqi Wan. BCSwinReg: A cross-modal attention network for CBCT-to-CT multimodal image registration. Computers in biology and medicine. vol 171. 2024-02-20. PMID:38377717. computed tomography (ct) and cone beam computed tomography (cbct) registration plays an important role in radiotherapy. 2024-02-20 2024-02-23 Not clear
Martina Moglioni, Pietro Carra, Silvia Arezzini, Nicola Belcari, Davide Bersani, Andrea Berti, Maria Giuseppina Bisogni, Marco Calderisi, Ilaria Ceppa, Piergiorgio Cerello, Mario Ciocca, Veronica Ferrero, Elisa Fiorina, Aafke Christine Kraan, Enrico Mazzoni, Matteo Morrocchi, Francesco Pennazio, Alessandra Retico, Valeria Rosso, Francesca Sbolgi, Viviana Vitolo, Giancarlo Sportell. Synthetic CT imaging for PET monitoring in proton therapy: a simulation study. Physics in medicine and biology. 2024-02-19. PMID:38373343. our model's performance stands on par with existing models relying on input from cone beam ct (cbct) or magnetic resonance imaging (mri), which contain more anatomical information than activity maps. 2024-02-19 2024-02-22 Not clear
Yanni Hu, Ziyang Hu, Wenjing Liu, Antian Gao, Shanhui Wen, Shu Liu, Zitong Li. Exploring the potential of ChatGPT as an adjunct for generating diagnosis based on chief complaint and cone beam CT radiologic findings. BMC medical informatics and decision making. vol 24. issue 1. 2024-02-19. PMID:38374067. exploring the potential of chatgpt as an adjunct for generating diagnosis based on chief complaint and cone beam ct radiologic findings. 2024-02-19 2024-02-22 Not clear
Julian W Lee, Steven Arild Wuyts Andersen, Bradley Hittle, Kimerly A Powell, Hagar Al-Fartoussi, Laura Banks, Zachary Brannen, Mariam Lahchich, Gregory J Wie. Variability in Manual Segmentation of Temporal Bone Structures in Cone Beam CT Images. Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. vol 45. issue 3. 2024-02-16. PMID:38361290. variability in manual segmentation of temporal bone structures in cone beam ct images. 2024-02-16 2024-02-18 Not clear
Nannan Cao, Ziyi Wang, Jiangyi Ding, Heng Zhang, Sai Zhang, Liugang Gao, Jiawei Sun, Kai Xie, Xinye N. A 4D-CBCT correction network based on contrastive learning for dose calculation in lung cancer. Radiation oncology (London, England). vol 19. issue 1. 2024-02-09. PMID:38336759. this study aimed to present a deep-learning network called contrastive learning-based cycle generative adversarial networks (clcgan) to mitigate streak artifacts and correct the ct value in four-dimensional cone beam computed tomography (4d-cbct) for dose calculation in lung cancer patients. 2024-02-09 2024-02-12 Not clear
Guangwen Zhu, Liting Xie, Xianwen H. Imaging of Merkel cell carcinoma of the eyelid: A case report. Oncology letters. vol 27. issue 3. 2024-02-05. PMID:38312913. head computed tomography (ct) and magnetic resonance imaging (mri) showed a space-occupying lesion ~2.8×2.4 cm in size outside the left orbital muscle cone, which was poorly demarcated from the surrounding normal tissues. 2024-02-05 2024-02-07 Not clear
Ashish Lanjekar, Monal M Kukde, Isha Madne, Komal R Deotale, Nandkishor J Banka. Pivotal Role of Ultrasonography and Radiology in Diagnosing a Case of Sialolith. Cureus. vol 15. issue 12. 2024-01-30. PMID:38288231. the patient was advised for necessary investigations, including an orthopantomogram, cone beam ct, neck ultrasound, and left submandibular gland sialography. 2024-01-30 2024-02-01 Not clear
Mohammad Atif, Nitesh Tewari, Manjari Reshikesh, Arnab Chanda, Vijay Prakash Mathur, Rahul Moranka. Methods and applications of finite element analysis in dental trauma research: A scoping review. Dental traumatology : official publication of International Association for Dental Traumatology. 2024-01-27. PMID:38279593. most studies utilized computed tomography (ct), cone beam ct, or micro ct. traumatic injury forces ranged from 100 n to 2000 n, and occlusal forces ranged from 150 n to 350 n. 2024-01-27 2024-01-29 Not clear