Reference |
Sentence |
Publish Date |
Extraction Date |
Species |
Jun-Ki Moon, Seonjeong Lee, Chul-Ho Kim, Jae Youn Yoon, Sunhyung Lee, Kang-Sik Lee, Pil Whan Yoo. Forte ceramic-on-delta ceramic cementless total hip arthroplasty: an 8- to 15-year follow-up study. Archives of orthopaedic and trauma surgery vol issue 2023 36871241 |
we aimed to investigate the clinical and radiological outcomes of cementless total hip arthroplasty (tha) with forte ceramic head on delta ceramic liner articulation. |
2023-03-05 |
2023-03-06 |
Not clear |
Young-Kyun Lee, Yong-Chan Ha, Samuel Jaeyoon Won, Jin-Hak Kim, Jung-Wee Park, Kyung-Hoi Ko. Mid-term Results of Revision Total Hip Arthroplasty Using Delta Ceramic-on-Ceramic Bearing. Clinics in orthopedic surgery vol 15 issue 1 2023 36778987 |
delta ceramic-on-ceramic (coc) articulation affords excellent outcomes in primary total hip arthroplasty (tha). |
2023-02-13 |
2023-03-06 |
Not clear |
Young-Kyun Lee, Yong-Chan Ha, Samuel Jaeyoon Won, Jin-Hak Kim, Jung-Wee Park, Kyung-Hoi Ko. Mid-term Results of Revision Total Hip Arthroplasty Using Delta Ceramic-on-Ceramic Bearing. Clinics in orthopedic surgery vol 15 issue 1 2023 36778987 |
this study aimed to report complications, radiological changes, clinical results, and survivorship of revision tha using delta coc articulation at minimum 5-year follow-up. |
2023-02-13 |
2023-03-06 |
Not clear |
Peter Bo J\\xc3\\xb8rgensen, Steffan Tabori-Jensen, Inger Mechlenburg, Morten Homilius, Torben B\\xc3\\xa6k Hansen, Maiken Stillin. Cemented and cementless dual mobility cups show similar fixation, low polyethylene wear, and low serum cobalt-chromium in elderly patients: a randomized radiostereometry study with 6 years' follow-up. Acta orthopaedica vol 93 issue 2022 36545926 |
dual mobility (dm) articulation total hip arthroplasty (tha) is used increasingly to reduce dislocation risk. |
2022-12-22 |
2023-01-30 |
Not clear |
Sebastien Lustig, Atul F Kamath, P Maxwell Courtney, Gwo-Chin Le. Dual-Mobility Articulations in Total Hip Arthroplasty: A Durable Game Changer or the Next Cause for Concern? Instructional course lectures vol 72 issue 2022 36534864 |
although the concept of dual-mobility articulation in tha is not new and early clinical experience dates back to the 1970s, its widespread use is a relatively recent phenomenon. |
2022-12-19 |
2023-01-30 |
Not clear |
Andrew Yun, Marilena Qutami, Eric Carle. Modular Dual Mobility Constructs Used for Recurrent Hip Instability. Cureus vol 13 issue 9 2021 34722041 |
conclusion refractory hip instability in tha may be effectively managed with an mdm articulation, even when prior attempts at surgical stabilization have failed. |
2021-11-02 |
2023-01-26 |
Not clear |
Young-Kyun Lee, Jae-Young Lim, Yong-Chan Ha, Tae-Young Kim, Woon-Hwa Jung, Kyung-Hoi Ko. Preventing ceramic liner fracture after Delta ceramic-on-ceramic total hip arthroplasty. Archives of orthopaedic and trauma surgery vol 141 issue 7 2021 32529389 |
the results of total hip arthroplasty (tha) with use of delta ceramic articulation were successful at medium term follow-up. |
2021-07-09 |
2023-01-26 |
Not clear |
Hyung-Gon Ryu, Young Ju Roh, Kwang-Jun Oh, Ji-Hyo Hwang, Yeesuk Kim, Hyun-Woo Cho, Sang-Min Ki. Dual mobility articulation total hip arthroplasty for displaced neck fracture in elderly with neuromuscular disorder. Injury vol 52 issue 6 2021 33461769 |
this study is prospectively conducted to investigate clinical performance and survivorship of total hip arthroplasty (tha) using dual mobility articulation in femoral neck fractures of elderly with neuromuscular disease. |
2021-06-17 |
2023-01-26 |
Not clear |
Pierre Georis, Thierry Thirion, Philippe Gille. Clinical and radiological results with a 36-mm cobalt-chrome prosthetic head, cross-linked Durasul liners associated with Allofit cups: a more than 10-year follow-up period. Hip international : the journal of clinical and experimental research on hip pathology and therapy vol 30 issue 4 2020 31431079 |
highly cross-linked polyethylene is currently a common articulation surface used for total hip arthroplasty (tha). |
2020-12-15 |
2023-01-26 |
Not clear |
Per-Erik Johanson, Bita Shareghi, Michael Eriksson, Johan K\\xc3\\xa4rrhol. Wear measurements with use of radiostereometric analysis in total hip arthroplasty with obscured femoral head. Journal of orthopaedic research : official publication of the Orthopaedic Research Society vol 38 issue 9 2020 32056282 |
however, several cup shell materials and articulation types used in total hip arthroplasty (tha) cannot be studied due to poor radiographic visibility of the femoral head (fh). |
2020-12-07 |
2023-01-26 |
Not clear |
Georgios Tsikandylakis, Soren Overgaard, Luigi Zagra, Johan K\\xc3\\xa4rrhol. Global diversity in bearings in primary THA. EFORT open reviews vol 5 issue 10 2020 33204520 |
choice of articulating materials, head size and the design of the articulation will become decisive for the long-term performance of a total hip arthroplasty (tha) and especially in terms of risk for dislocation and wear-related problems. |
2020-11-19 |
2023-01-26 |
Not clear |
Jun-Il Yoo, Yong-Chan Ha, Dong-Hyun Kim, Young-Kyun Lee, Kyung-Hoi Ko. Total Hip Arthroplasty Using Hybrid Ceramic Bearing: A Minimum 10-Year Followup Study. Indian journal of orthopaedics vol 53 issue 5 2020 31488933 |
contemporary ceramic articulation in total hip arthroplasty (tha) has shown successful clinical and radiologic outcomes at mid-to-long term. |
2020-10-01 |
2023-01-26 |
Not clear |
Jun-Il Yoo, Yong-Chan Ha, Dong-Hyun Kim, Young-Kyun Lee, Kyung-Hoi Ko. Total Hip Arthroplasty Using Hybrid Ceramic Bearing: A Minimum 10-Year Followup Study. Indian journal of orthopaedics vol 53 issue 5 2020 31488933 |
the purpose of this study was to evaluate clinicoradiological outcomes, ceramic-related complications, and survivorship of tha with the use of hybrid ceramic bearing; biolox delta liner-on-biolox forte head articulation at a minimum followup of 10 years. |
2020-10-01 |
2023-01-26 |
Not clear |
Kyu-Jin Cho, Kyung-Soon Park, Won-Young Jang, Chun-Gon Park, Taek-Rim Yoo. Midterm Results of Fourth-Generation Ceramic-On-Ceramic Total Hip Arthroplasty. Indian journal of orthopaedics vol 53 issue 5 2020 31488932 |
there are limited reports for the results of the fourth-generation ceramic-on-ceramic (coc) articulation total hip arthroplasty (tha). |
2020-10-01 |
2023-01-26 |
Not clear |
Kyu-Jin Cho, Kyung-Soon Park, Won-Young Jang, Chun-Gon Park, Taek-Rim Yoo. Midterm Results of Fourth-Generation Ceramic-On-Ceramic Total Hip Arthroplasty. Indian journal of orthopaedics vol 53 issue 5 2020 31488932 |
the objective of this study was to evaluate the incidence, risk factors of delta ceramic liner or head fractures, and also the clinical and radiological results of using the fourth-generation coc articulation in tha. |
2020-10-01 |
2023-01-26 |
Not clear |
Yoni M Blau, Andrew J Meyers, Mauro Giordani, John P Meeha. Pseudotumor in ceramic-on-metal total hip arthroplasty. Arthroplasty today vol 3 issue 4 2020 29204484 |
adverse local tissue reaction/pseudotumor and elevated serum metal ion levels are commonly reported complications encountered in metal-on-metal tha, while audible articulation and rim fracture are reported in ceramic-on-ceramic tha. |
2020-10-01 |
2023-01-26 |
Not clear |
Lokesh Gudda Naik, Won Yong Shon, I C Clarke, Jun-Gyu Moon, Piyush Mukund, Sang-Min Ki. Pseudotumor and Subsequent Implant Loosening as a Complication of Revision Total Hip Arthroplasty with Ceramic-on-Metal Bearing: A Case Report. Hip & pelvis vol 30 issue 4 2020 30534547 |
pseudotumors are not uncommon complications after total hip arthroplasty (tha) and may occur due to differences in bearing surfaces of the head and the liner ranging from soft to hard articulation. |
2020-09-30 |
2023-01-26 |
Not clear |
Onur Kocadal, Turhan Ozler, Alp Er Tunga Bolukbasi, Faik Altinta. Non-traumatic Ceramic Head Fracture in Total Hip Arthroplasty with Ceramic-on-Ceramic Articulation at Postoperative 16th Years. Hip & pelvis vol 31 issue 2 2020 31198780 |
ceramic articulation has gained popularity in total hip arthroplasty (tha); however, one of the most important concerns about the use of ceramic materials is the potential for breakage. |
2020-09-29 |
2023-01-26 |
Not clear |
Chan-Woo Park, Joo-Hwan Kim, Seung-Jae Lim, Young-Wan Moon, Youn-Soo Par. A Minimum of 15-Year Results of Cementless Total Hip Arthroplasty Using a 28-mm Metal-On-Metal Articulation. The Journal of arthroplasty vol 34 issue 7 2020 30930158 |
we previously reported unexpected early failures of total hip arthroplasty (tha) utilizing a 28-mm ultima metal-on-metal (mom) articulation. |
2020-05-21 |
2023-01-26 |
Not clear |
Anders Persson, Thomas Eisler, Henrik Bod\\xc3\\xa9n, Ferid Krupic, Olof Sk\\xc3\\xb6ldenberg, Olav Mure. Revision for Symptomatic Pseudotumor After Primary Metal-on-Polyethylene Total Hip Arthroplasty with a Standard Femoral Stem. The Journal of bone and joint surgery. American volume vol 100 issue 11 2019 29870445 |
the purpose of this study was to determine the prevalence of revision surgery for symptomatic pseudotumors in a large cohort of patients treated with primary tha with a standard stem and a non-mom articulation. |
2019-09-09 |
2023-01-26 |
Not clear |