All Relations between cup and Thalamus

Publication Sentence Publish Date Extraction Date Species
Hideaki Miyoshi, Hiroshi Mikami, Koichi Oba, Rui Amar. Anteversion of the acetabular component aligned with the transverse acetabular ligament in total hip arthroplasty. The Journal of arthroplasty. vol 27. issue 6. 2013-01-02. PMID:22153949. we suggest that the transverse acetabular ligament is a practical anatomical landmark for determining cup anteversion in tha for both dysplastic and nondysplastic hip cases. 2013-01-02 2023-08-12 Not clear
Hirohito Abe, Takashi Sakai, Toshimitsu Hamasaki, Masaki Takao, Takashi Nishii, Nobuo Nakamura, Nobuhiko Sugan. Is the transverse acetabular ligament a reliable cup orientation guide? Acta orthopaedica. vol 83. issue 5. 2013-01-01. PMID:22974185. it is controversial whether the transverse acetabular ligament (tal) is a reliable guide for determining the cup orientation during total hip arthroplasty (tha). 2013-01-01 2023-08-12 Not clear
Ronald Veldstra, Annemarie van Dongen, Eric C Kraanevel. Comparing alumina-reduced and conventional surface grit-blasted acetabular cups in primary THA: early results from a randomised clinical trial. Hip international : the journal of clinical and experimental research on hip pathology and therapy. vol 22. issue 3. 2012-12-11. PMID:22740283. in a randomised controlled, double-blind study, patients with primary or secondary osteoarthritis requiring primary arthroplasty were randomly assigned to tha with either the bicon-plus or bicon-plus nt cup. 2012-12-11 2023-08-12 Not clear
Florian Schmidutz, Andreas Fottner, Lorenz Wanke-Jellinek, Arnd Steinbrück, Volkmar Jansson, Farhad Mazzochia. Hip resurfacing requires larger acetabular cups than conventional hip replacement: a comparative analysis of 100 hips, based on radiographic templating. Acta orthopaedica Belgica. vol 78. issue 4. 2012-11-13. PMID:23019781. acetabular bone loss is a matter for concern in hip resurfacing arthroplasty (hra), as preservation of the femoral head and neck might demand a larger acetabular cup than in total hip arthroplasty (tha). 2012-11-13 2023-08-12 Not clear
Florian Schmidutz, Andreas Fottner, Lorenz Wanke-Jellinek, Arnd Steinbrück, Volkmar Jansson, Farhad Mazzochia. Hip resurfacing requires larger acetabular cups than conventional hip replacement: a comparative analysis of 100 hips, based on radiographic templating. Acta orthopaedica Belgica. vol 78. issue 4. 2012-11-13. PMID:23019781. using radiographic templating, the cup size required for either tha or hra was calculated on 100 pelvic films. 2012-11-13 2023-08-12 Not clear
Florian Schmidutz, Andreas Fottner, Lorenz Wanke-Jellinek, Arnd Steinbrück, Volkmar Jansson, Farhad Mazzochia. Hip resurfacing requires larger acetabular cups than conventional hip replacement: a comparative analysis of 100 hips, based on radiographic templating. Acta orthopaedica Belgica. vol 78. issue 4. 2012-11-13. PMID:23019781. the average cup size required for hra was larger than for tha (delta + 1.1 mm). 2012-11-13 2023-08-12 Not clear
Florian Schmidutz, Andreas Fottner, Lorenz Wanke-Jellinek, Arnd Steinbrück, Volkmar Jansson, Farhad Mazzochia. Hip resurfacing requires larger acetabular cups than conventional hip replacement: a comparative analysis of 100 hips, based on radiographic templating. Acta orthopaedica Belgica. vol 78. issue 4. 2012-11-13. PMID:23019781. the cup size for hra and tha was similar in 49% of hips; in 51% of the hips the cup required for hra was larger: one size larger in 31%, two sizes larger in 18% and three sizes larger in 2% of the cases. 2012-11-13 2023-08-12 Not clear
Florian Schmidutz, Andreas Fottner, Lorenz Wanke-Jellinek, Arnd Steinbrück, Volkmar Jansson, Farhad Mazzochia. Hip resurfacing requires larger acetabular cups than conventional hip replacement: a comparative analysis of 100 hips, based on radiographic templating. Acta orthopaedica Belgica. vol 78. issue 4. 2012-11-13. PMID:23019781. this study shows that hra requires a larger acetabular cup in more than 50% of the cases compared to tha. 2012-11-13 2023-08-12 Not clear
Florian Schmidutz, Andreas Fottner, Lorenz Wanke-Jellinek, Arnd Steinbrück, Volkmar Jansson, Farhad Mazzochia. Hip resurfacing requires larger acetabular cups than conventional hip replacement: a comparative analysis of 100 hips, based on radiographic templating. Acta orthopaedica Belgica. vol 78. issue 4. 2012-11-13. PMID:23019781. when planning hra surgeons should remember that cup size is determined by the size of the matching femoral component and that size difference with tha increases with increasing hip sizes. 2012-11-13 2023-08-12 Not clear
G Zheng, J von Recum, L-P Nolte, P A Grützner, S D Steppacher, J Frank. Validation of a statistical shape model-based 2D/3D reconstruction method for determination of cup orientation after THA. International journal of computer assisted radiology and surgery. vol 7. issue 2. 2012-09-12. PMID:21792672. validation of a statistical shape model-based 2d/3d reconstruction method for determination of cup orientation after tha. 2012-09-12 2023-08-12 Not clear
Nicholas M Bernthal, Paul C Celestre, Alexandra I Stavrakis, John C Ludington, Daniel A Oake. Disappointing short-term results with the DePuy ASR XL metal-on-metal total hip arthroplasty. The Journal of arthroplasty. vol 27. issue 4. 2012-09-11. PMID:22000575. the high rate of implant dysfunction at early follow-up suggests serious concerns with the concept of mom tha with an ultralarge-diameter femoral head paired with a monoblock acetabular cup. 2012-09-11 2023-08-12 Not clear
Masayuki Kyomoto, Toru Moro, Kenichi Saiga, Masami Hashimoto, Hideya Ito, Hiroshi Kawaguchi, Yoshio Takatori, Kazuhiko Ishihar. Biomimetic hydration lubrication with various polyelectrolyte layers on cross-linked polyethylene orthopedic bearing materials. Biomaterials. vol 33. issue 18. 2012-08-09. PMID:22465336. thus, such nanometer-scaled hydrophilic polymers or polyelectrolyte layers on the clpe surface of acetabular cup bearings could confer high durability to tha prosthetics. 2012-08-09 2023-08-12 Not clear
Daniel J Dalug. Accuracy of the acetabular index using the percutaneous assisted total hip technique. American journal of orthopedics (Belle Mead, N.J.). vol 41. issue 2. 2012-08-02. PMID:22482091. this article describes a series of 74 consecutive primary thas (71 patients, 3 bilateral) performed using a percutaneous assisted tha technique that does not require navigation, yet allows adequate visualization for accurate acetabular cup placement. 2012-08-02 2023-08-12 Not clear
Takashi Murayama, Hideo Ohnishi, Satoshi Okabe, Hiroshi Tsurukami, Toshiharu Mori, Nariaki Nakura, Soshi Uchida, Akinori Sakai, Toshitaka Nakamur. 15-year comparison of cementless total hip arthroplasty with anatomical or high cup placement for Crowe I to III hip dysplasia. Orthopedics. vol 35. issue 3. 2012-07-12. PMID:22385439. this study compared radiological and clinical results of mallory-head (biomet, warsaw, indiana) cementless total hip arthroplasty (tha) by anatomical (ap group) or high cup placement (hp group) for crowe i to iii developmental dysplasia of the hip. 2012-07-12 2023-08-12 Not clear
Alessandro Carcangiu, Carmelo D'Arrigo, Domenico Topa, Raffaella Alonzo, Attilio Speranza, Stefania De Sanctis, Andrea Ferrett. Reliability of cup position in navigated THA in the lateral decubitus position using the 'flip technique'. Hip international : the journal of clinical and experimental research on hip pathology and therapy. vol 21. issue 6. 2012-04-24. PMID:22135017. reliability of cup position in navigated tha in the lateral decubitus position using the 'flip technique'. 2012-04-24 2023-08-12 Not clear
Alessandro Carcangiu, Carmelo D'Arrigo, Domenico Topa, Raffaella Alonzo, Attilio Speranza, Stefania De Sanctis, Andrea Ferrett. Reliability of cup position in navigated THA in the lateral decubitus position using the 'flip technique'. Hip international : the journal of clinical and experimental research on hip pathology and therapy. vol 21. issue 6. 2012-04-24. PMID:22135017. we report 24 patients affected by primary osteoarthritis undergoing tha in which implants were placed with a conventional free-hand technique using the acetabular transverse ligament for cup orientation. 2012-04-24 2023-08-12 Not clear
T Renkawitz, M Wörner, E Sendtner, M Weber, P Lechler, J Grifk. [Principles and new concepts in computer-navigated total hip arthroplasty]. Der Orthopade. vol 40. issue 12. 2012-04-17. PMID:22095457. combined component placement of cup and stem is closely correlated to stability, functionality and wear in total hip replacement (tha). 2012-04-17 2023-08-12 Not clear
Elhadi Sariali, Todd Stewart, Zhongmin Jin, John Fishe. Effect of cup abduction angle and head lateral microseparation on contact stresses in ceramic-on-ceramic total hip arthroplasty. Journal of biomechanics. vol 45. issue 2. 2012-04-16. PMID:22119582. both cup abduction and lateral microseparation displacement induced a large increase in the stresses in ceramic-on-ceramic tha. 2012-04-16 2023-08-12 Not clear
Robin Peter, Anne Lübbeke, Richard Stern, Pierre Hoffmeye. Cup size and risk of dislocation after primary total hip arthroplasty. The Journal of arthroplasty. vol 26. issue 8. 2012-04-12. PMID:21414747. we evaluated the relationship between cup diameter and dislocation risk in patients undergoing primary total hip arthroplasty (tha) with a 28-mm head. 2012-04-12 2023-08-12 Not clear
Robin Peter, Anne Lübbeke, Richard Stern, Pierre Hoffmeye. Cup size and risk of dislocation after primary total hip arthroplasty. The Journal of arthroplasty. vol 26. issue 8. 2012-04-12. PMID:21414747. patients with tha (28-mm head) had more than twice the risk of dislocation with cup size of 56 mm or higher compared to patients with smaller cups. 2012-04-12 2023-08-12 Not clear